gogo
Amazon cover image
Image from Amazon.com

National rules for electrical installations in potentially explosive atmospheres /. Electro-Technical Council of Ireland.

Contributor(s): Material type: TextTextPublication details: Dublin : Electro-Technical Council of Ireland, 2001.Edition: 2nd ed., ET 105 : 2001Description: vii, 72 p. : ill. ; 29 cmISBN:
  • 9780953938018:
  • 0953938018
Subject(s): DDC classification:
  • 621.3
Online resources:
Contents:
Foreword -- The Electro Technical Council of Ireland -- Introduction
Sections: -- Scope -- Normative references -- Definitions --General requirements -- Selection of apparatus: gases, vapours and mists -- Earthing arrangements, protective conductors and equipotential bonding -- Electrical protection, emergency switch off and electrical isolation -- Wiring systems in hazardous areas -- Additional requirements for type of protection 'i' -- Additional requirements for type of protection 'd' -- Additional requirements for type of protection 'e' -- Additional requirements for apparatus for use in zone 2 -- Electrical installations in the presence of ignitable dusts -- Personal electrical apparatus -- Maintenance -- Verification, inspection and testing.
Annex : IP classification system for enclosures -- categories and zones -- List of national safety legislation -- Temperatures of conductors (normal and fault conditions) -- Marking of apparatus -- Selection of the maximum surface temperature marking for equipment subject to dust layes -- Examples of dust layers of excessive thickness -- Clearances for Ex 'e' terminations -- Examples of mixed wiring systems -- Determination of cable parameters -- Verification of intrinsically safe circuits with more than one associated apparatus with linear current/voltage characteristics
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Reference Carlow Campus Library Reference 621.3 (Browse shelf(Opens below)) 1 Not for loan 54105

Includes index.

Includes index.

Foreword -- The Electro Technical Council of Ireland -- Introduction

Sections: -- Scope -- Normative references -- Definitions --General requirements -- Selection of apparatus: gases, vapours and mists -- Earthing arrangements, protective conductors and equipotential bonding -- Electrical protection, emergency switch off and electrical isolation -- Wiring systems in hazardous areas -- Additional requirements for type of protection 'i' -- Additional requirements for type of protection 'd' -- Additional requirements for type of protection 'e' -- Additional requirements for apparatus for use in zone 2 -- Electrical installations in the presence of ignitable dusts -- Personal electrical apparatus -- Maintenance -- Verification, inspection and testing.

Annex : IP classification system for enclosures -- categories and zones -- List of national safety legislation -- Temperatures of conductors (normal and fault conditions) -- Marking of apparatus -- Selection of the maximum surface temperature marking for equipment subject to dust layes -- Examples of dust layers of excessive thickness -- Clearances for Ex 'e' terminations -- Examples of mixed wiring systems -- Determination of cable parameters -- Verification of intrinsically safe circuits with more than one associated apparatus with linear current/voltage characteristics

52.75

Powered by Koha